Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
1.
Braz. j. otorhinolaryngol. (Impr.) ; 87(3): 269-273, May-Jun. 2021. graf
Article in English, Portuguese | LILACS | ID: biblio-1285696

ABSTRACT

Abstract Introduction Recurrent epistaxis is commonly encountered in the rhinology outpatient clinic. Under endoscopic guidance, both bipolar cautery and monopolar forceps (combined with suction) have been employed to control the bleeding. However, the use of monopolar forceps requires the placement of grounding pads. Most procedures are currently performed in operating rooms. Objective We investigated outcomes after the use of Microwave Ablation (MWA) to control epistaxis in adults with isolated mucosal bulge lesions. All procedures were performed with patients under local anesthesia in our outpatient clinic. Methods This is a retrospective cohort study. We included 83 adults with epistaxis of isolated mucosal bulge lesions. Microwave ablation was performed in the outpatient clinic to control bleeding, after induction of local anesthesia. The primary outcome was successful hemostasis. The secondary outcomes were the rebleeding rates at weeks 1 and 4 and month 6, and complications (crust or synechiae formation, septal perforation, and/or orbit or brain complications). Results All bleeding points were successfully ablated; hemostasis was achieved within 1-2 min. The mean pain score was 1.83 intra-operatively and 0.95 1 h postoperatively. No patient re-bled, and no severe MWA-related complication (septal perforation, synechiae formation, or orbit or brain complication) was recorded to 6 months of follow-up. Conclusions Endoscopic microwave ablation with patients under local anesthesia is a novel, safe, effective, rapid, well-tolerated, outpatient treatment for adults with epistaxis of isolated mucosal bulge lesions, especially those for whom general anesthesia might be risky, those with electrical implants, and those exhibiting contraindications for arterial embolization.


Resumo Introdução Epistaxe recorrente é comumente encontrada no ambulatório de rinologia. Sob orientação endoscópica, foram empregados tanto o cautério bipolar quanto a pinça monopolar (combinados à sucção) para controlar a condição. No entanto, o uso de pinças monopolares requer a colocação de placas de aterramento. Atualmente, a maioria dos procedimentos é feita em salas de cirurgia. Objetivo Investigamos os resultados após o uso da ablação por micro-ondas (MWA, do inglês Microwave Ablation) no controle da epistaxe em adultos com lesões isoladas protuberantes da mucosa. Todos os procedimentos foram feitos em nosso ambulatório com os pacientes sob anestesia local. Métodos Estudo de coorte retrospectivo. Foram incluídos 83 adultos com epistaxe de lesões isoladas protuberantes da mucosa. A ablação por micro-ondas foi feita no ambulatório para controlar o sangramento, após a administração de anestesia local. O desfecho primário foi uma hemostasia bem-sucedida. Os desfechos secundários foram as taxas de ressangramento, nas semanas 1 e 4 e no mês 6, e complicações (formação de crostas ou sinéquias, perfuração septal e/ou complicações orbitais ou cerebrais). Resultados Todos os pontos de sangramento foram contidos com sucesso; a hemostasia foi alcançada em 1-2 minutos. O escore médio de dor foi de 1,83 no intraoperatório e de 0,95 1 h no pós-operatório. Nenhum paciente apresentou ressangramento e nenhuma complicação grave relacionada à MWA (perfuração septal, formação de sinéquias ou complicações orbitais ou cerebrais) foi registrada em 6 meses de seguimento. Conclusões A ablação endoscópica por micro-ondas com pacientes sob anestesia local é um tratamento ambulatorial novo, seguro, eficaz, rápido e bem tolerado para adultos com epistaxe de lesões isoladas protuberantes da mucosa, especialmente aqueles para os quais a anestesia geral pode ser arriscada, indivíduos com implantes elétricos e aqueles com contraindicações para embolização arterial.


Subject(s)
Humans , Adult , Epistaxis/etiology , Microwaves/therapeutic use , Outpatients , Retrospective Studies , Treatment Outcome , Hemostasis
2.
RGO (Porto Alegre) ; 68: e20200035b, 2020. graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1136033

ABSTRACT

ABSTRACT Appropriate sterilization methods for dental substrate are necessary so that extracted teeth can be used in laboratory activities, since potentially pathogenic microorganisms may be present even if teeth have been cleaned. Objective Evaluating the sterilization process of human teeth performed by microwave irradiation and autoclave sterilization. Methods Fifty human premolar teeth were sectioned in two portions and distributed in two test groups: G1 - autoclave sterilization for 20 minutes, 1Kgf/cm2, at 127ºC; G2 - Microwave irradiation in a recipient containing 100ml of distilled water, 900W for 5 minutes. Before and after the decontamination process, all teeth were immersed in Brain Heart Infusion (BHI) broth to verify their contamination (positive control) and decontamination potential respectively. Results The statistical analysis of the Friedman test (p <0.05) showed that all the tested sterilization methods were statistically effective. Conclusion These results show that both autoclaving and microwave irradiation are effective alternatives for the sterilization of human teeth.


RESUMO Métodos de esterilização do substrato dental são necessários para que os dentes extraídos possam ser utilizados em atividades laboratoriais, pois microrganismos potencialmente patogênicos estão presentes mesmo em dentes que foram limpos. Objetivo Avaliar o processo de esterilização de dentes humanos em autoclave e microondas. Métodos Cinquenta dentes pré-molares humanos foram seccionados em duas porções e distribuídos em dois grupos de teste: G1 - esterilização em autoclave por 20 minutos, 1Kgf / cm2, a 127ºC; G2 - Irradiação por microondas em um recipiente contendo 100ml de água destilada, 900W por 5 minutos. Antes e após o processo de descontaminação, todos os dentes foram imersos em caldo Brain Heart Infusion (BHI) para verificar sua contaminação (controle positivo) e potencial de descontaminação, respectivamente. Resultados A análise estatística do teste de Friedman (p < 0,05) mostrou que todos os métodos de esterilização testados foram estatisticamente eficazes. Conclusão Esses resultados mostram que tanto a autoclave quanto a irradiação por microondas são alternativas eficazes para a esterilização de dentes humanos.

3.
Hig. aliment ; 33(288/289): 905-909, abr.-maio 2019. tab
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1482067

ABSTRACT

Objetivou-se avaliar a maciez de lombos suínos (M. Longissimus thoracis) de diferentes classes de qualidade (RFN, PSE e RSE) por dois métodos de cozimento (micro-ondas e grelha) e dois protocolos (SSF e WBsSF) de determinação de força de cisalhamento (FC). As classes de qualidade de carne suína não difeririam (P>0,05) quanto a FC, independentemente do método de cozimento ou protocolo de cisalhamento usado. Maior repetibilidade da FC foi observada quando do cozimento em micro-ondas (SSF = 0,77; WBsSF = 0,75), tendo alta correlação (r = 0,72) entre os dois protocolos. Concluiu-se que que as classes de qualidade da carne suína não diferem quanto à maciez instrumental e que o cozimento em micro-ondas associado ao protocolo SSF é altamente promissor para avaliação da maciez instrumental da carne suína.


Subject(s)
Animals , Meat/analysis , Cooking/methods , Shear Strength , Food Quality , Swine
4.
Biosci. j. (Online) ; 34(3): 629-639, mai/jun. 2018. tab
Article in English | LILACS | ID: biblio-966920

ABSTRACT

The objective of this work was to evaluate the chemical composition of essential oil from Varronia curassavica Jacq. obtained by microwave (MI) and hydrodistillation (HD) extraction methods. The MI method tested three powers (500, 600, and 700W), three distillation times (20, 30, and 40 min.), and three water volumes (0, 25, and 50 mL per sample). The HD method tested three distillation times (100, 120, and 140 min.) and three water volumes (1.0, 1.5, and 2.0 L per 3-liter flask). The essential oils were analyzed by GC/MS-FID. The optimal condition for the essential oil extraction by the MI method was 700W for 40 min. (3.28%), regardless of the volume of water. In its turn, the best condition for essential oil extraction by the HD method was 120 min. with 1.0 L of water per flask (3.34%). The most abundant compounds for MI (700 W for 40 min. without water) were shyobunol (26.53%) and bicyclogermacrene (4.96%); and the most abundant compounds for HD (120 min. with 1.0 L of water/flask) were shyobunol (24.00%) and germacrene D-4-ol (10.23%). Methyl farnesoate (2E, 6E) and farnesyl acetate (2Z, 6E) were not detected in the essential oil extracted by HD; however, they were identified by the MI method. By increasing the distillation time and/or volume of water in HD, a reduction was observed for the content of the chemical compounds -elemene (from 1.23 to 0.97%), Ecaryophyllene (from 5.49 to 4.35%), -humulene (from 1.80 to 1.43%), alloaromadendrene (from 1.78 to 1.44%), bicyclogermacrene (from 5.63 to 4.55%), and germacrene D-4-ol (from 11.40 to 9.86%). Power, extraction time, and their interactions influenced the content of essential oil obtained by microwave extraction (MI). Within each power, the highest essential oil content was extracted at the longest distillation time (40 min.), except for 600W, where no significant difference was detected between 30 and 40 min. The optimal essential oil contents for both extraction methods were statically similar by the t-test for dependent samples. However, the MI method presents advantages, such as shorter distillation time and less energy and water consumption.


O objetivo deste trabalho foi avaliar a composição química do óleo essencial de Varronia curassavica Jacq. obtido pelos métodos de extração micro-ondas (MI) e hidrodestilação (HD). Para MI, foram testadas três potências (500, 600 e 700W), três tempos de destilação (20, 30 e 40 min.) e três volumes de água (0, 25 e 50 mL por amostra). Para HD, foram testados três tempos de destilação (100, 120 e 140 min.) e três volumes de água (1,0; 1,5 e 2,0 L por balão de 3 litros). Os óleos essenciais foram analisados por CG/EM-FID. Maiores teores de óleo essencial foram obtidos nas condições de 700 W por 40 min. (3.28%), independente do volume de água para MI, e 120 min. com 1,0 L de água por balão para HD (3,34%). Os compostos mais abundantes para MI (700W, por 40 min., sem água) foram o shyobunol (26,53%) e biciclogermacreno (4,96%) e para HD (120 min. com 1,0 L de água /balão) foram shyobunol (24,00%) e germacreno D -4 -ol (10,23%). Metil farnesoato (2E, 6E) e farnesil acetato (2Z, 6E) não foram detectados no óleo essencial extraído por HD, porém, foram detectados nas amostras extraídas por MI. Com o aumento do tempo de destilação e/ou do volume de água em HD, houve redução no conteúdo dos constituintes químicos -elemeno (de 1,23 para 0,97%), E-cariofileno (de 5,49 para 4,35%), -humuleno (1,80 para 1,43%), aloaromadendreno (de 1,78 para 1,44%), biciclogermacreno (de 5,63 para 4,55%) e germacreno D-4-ol (de 11,40 para 9,86%). A potência, o tempo de extração e suas interações influenciaram no teor de óleo essencial obtido na extração por micro-ondas (MI). Dentro de cada potência, o maior teor de óleo essencial foi obtido no tempo mais longo de extração (40 min.), exceto para 600 W, que não apresentou diferença significativa entre 30 e 40 min. Nas condições ótimas de extração, os teores de óleo essencial obtidos foram estatisticamente semelhantes pelo teste t para amostras dependentes. No entanto, a extração por micro-ondas apresenta algumas vantagens em relação a HD, como menor tempo de destilação e menor consumo de energia e água.


Subject(s)
Oils, Volatile , Distillation
5.
São José dos Campos; s.n; 2018. 52 p. il., tab., graf..
Thesis in Portuguese | LILACS, BBO | ID: biblio-906910

ABSTRACT

O objetivo deste trabalho foi avaliar o efeito da fadiga na microestrutura de uma cerâmica odontológica (Y-TZP) sinterizada pelo método convencional ou por energia de micro-ondas. A hipótese nula foi que a fadiga não irá gerar alterações na microestrutura deste material. Para isto, foram confeccionados, por meio de um sistema CAD/CAM, 84 discos de zircônia (VIPI block zircon) com características finais de 12 mm de diâmetro e 1,2 mm de espessura conforme a norma ISO 6872. Os espécimes foram separados em dois grupos: Grupo I ­ Sinterização convencional: ciclo estabelecido pelo fabricante (2 horas a 1530 °C) e Grupo II ­ sinterização por energia de micro-ondas (15 min a 1450 °C). Dez amostras por grupo foram submetidas ao teste monotônico (1000 KgF ­ 1mm/min) para a determinação da carga para fratura, utilizada como parâmetro para os testes de fadiga (método step-stress e fadiga dinâmica). O teste de fadiga step-stress foi realizado utilizando 4 perfis de carga, ultra-suave, suave, moderado e agressivo, até que ocorresse a fratura. A fadiga dinâmica foi realizada com o ensaio dos discos até fratura sob cinco taxas de tensão (1, 0,1, 0,01, 0,001 e 0,0001 MPa/s), e a partir disso foram calculados o coeficiente de crescimento de trincas e módulo de Weibull (confiabilidade) para cada grupo. Foram realizadas análises complementares de densidade, translucidez, microscopia eletrônica de varredura (MEV) e difratometria de Raios-X (DRX) de ambos os grupos para a caracterização dos materiais. Os resultados da fadiga step-stress não mostraram diferenças no comportamento dos espécimes de cada grupo. Na fadiga dinâmica, os métodos de fadiga também não mostraram diferenças no comportamento e tiveram coeficientes de crescimento de trinca similares. O modulo de Weibull mostrou maiores valores de confiabilidade para o grupo micro-ondas (m = 7,9) do que para o grupo de sinterização convencional (m = 6,7). Os valores de densidade também foram semelhantes para os grupos estudados, já a translucidez foi menor para o grupo micro-ondas. As imagens de MEV mostraram microestruturas similares entre grupos, apenas uma diferença no tamanho dos grãos foi observada, 0,53 µm para os grãos de microondas e 0,89 µm para os grãos dos espécimes sinterizados convencionalmente. Conclui-se que o processo de sinterização por microondas pode ser aplicado como alternativa de sinterização de zirconia ao dia-a dia laboratorial(AU)


The objective of this work was to evaluate the microstructure and fatigue behavior of a dental ceramic (Y-TZP) sintered by conventional method or by microwave energy. The null hypothesis was that the fatigue will not effect the microstructure of this material. 84 zirconia discs (VIPI block zircon) with final characteristics of 12 mm in diameter and 1.2 mm in thickness according to ISO 6872 were made using a CAD/CAM system. The specimens were divided in two groups: Group I - Conventional sintering: cycle established by the manufacturer (2 hours at 1530 °C) and Group II - sintering by microwave energy (15 min at 1450 °C). Ten samples per group were submitted to monotonic test (1000 KgF - 1mm/min) to determine the load to fracture, used as a parameter for fatigue tests (step-stress and dynamic fatigue). The step-stress fatigue test was performed using 4 load profiles, ultramild, mild, moderate and aggressive, until the fracture. The dynamic fatigue was performed by testing the disks to fracture under five constant stress rates (1, 0.1, 0.01, 0.001 and 0.0001 MPa/s), and from this the crack growth coefficient and Weibull module (reliability) were measured for each group. Additional analyzes of density, translucency, scanning electron microscopy (SEM) and X-ray diffractometry (XRD) for both groups were carried out to characterize the materials. The results of stepstress fatigue test did not show differences in the specimens behavior of each group. Dynamic fatigue also showed no differences in behavior and had similar crack growth coefficients. The Weibull modulus showed higher reliability values for the microwave group (m = 7.9) than for the conventional sintering group (m = 6.7). The density values were also similar for the studied groups, since the translucency was lower for the microwave group. SEM images showed similar microstructures between groups, only a difference in grain size was observed, 0.53 µm for microwave grains and 0.89 µm for the conventionally-sintered grains. It is concluded that the microwave sintering process can be applied as an alternative to zirconia sintering to daily laboratory work(AU)


Subject(s)
Humans , Ceramics/adverse effects , Materials Science/adverse effects , Microwaves
6.
Ciênc. rural (Online) ; 48(7): e20170883, 2018. tab
Article in English | LILACS | ID: biblio-1045165

ABSTRACT

ABSTRACT: Dairy products are a common staple in the human diet. Moisture content is an important factor in the composition of foods, and it is a parameter used to measure product quality due to its direct influence on food storage. In this study, the moisture contents of three different products (mozzarella cheese, a creamy cheese spread, and yogurt drinks) were measured using oven drying, infrared drying, and microwave drying in order to compare the results of these three methods. Three brands of each product were used, all of which were purchased at the local supermarket in the city of Goiatuba, Goiás, Brazil. The different methods used to measure the dry extract of most of the brands analyzed did not differ significantly between each other based on a significance level of 5% on Tukey's test. There was a significant difference between the methodologies used in the case of only one brand of each analyzed product. Microwave drying method wasreported to be a safe and reliable technique for analyzing dry extract from dairy products; it produces precise results, thus guaranteeing the quality of the analysis, and it reduces procedure time, thus optimizing the routine analytical processes performed in quality control laboratories within food processing plants.


RESUMO: Os produtos lácteos fazem parte da alimentação humana e o teor de umidade é uma informação importante da composição de alimentos e está entre os parâmetros da qualidade dos produtos, pois apresenta influência direta no armazenamento dos mesmos. Foram realizadas análises de umidade pela metodologia de secagem em estufa, infravermelho e micro-ondas em três produtos diferentes, sendo estes a mussarela, o queijo cremoso e a bebida láctea, com a utilização de três marcas distintas para cada produto, todas adquiridas no comércio local da cidade de Goiatuba, Goiás. Os diferentes métodos de determinação de extrato seco utilizados não diferiram significativamente entre si a um nível de significância de 5% pelo teste de Tukey, para a maioria das marcas comerciais analisadas. Houve diferença significativa, entre as metodologias utilizadas apenas para uma marca, para cada produto analisado. A metodologia de secagem em micro-ondas é um método seguro e confiável em análises de extrato seco em derivados lácteos, com resultados precisos garantindo a qualidade nos processos analíticos, como também a redução do tempo de análise garantindo a otimização desse processo nas análises de rotina em laboratórios de controle de qualidade das indústrias alimentícias.

7.
RGO (Porto Alegre) ; 65(1): 8-12, Jan.-Mar. 2017. tab
Article in English | LILACS | ID: biblio-842369

ABSTRACT

ABSTRACT Objective: The aim of this study is to analyze if both color and nylon fibers have an influence on microwave-cured acrylic resin properties. Methods: Rectangular and disk-shaped specimens were prepared using acrylic resins; medium pink with and without nylon fibers and colorless without nylon fibers. To obtain the rectangular specimens, a stainless steel die was used with the following dimensions: 64 X 10 x 3 mm (± 0.5mm). To obtain disk-shaped specimens, a die 50mm (±0.5mm) in diameter and 0.5mm (±0.05mm) thick was employed. They were randomized to form groups: control (colorless acrylic) and experimental (medium pink, with and without nylon fibers), with each group consisting of ten (10) specimens rectangular in shape and five (5) disk-shaped. They were analyzed in six (6) assays (izod impact strength, n=10; Knoop hardness, n=10; glass transition temperature, n=3; water sorption and solubility, n=5; degree of monomer/polymer conversion, n=1; flexural strength and flexural modulus, n=10). All variables were subjected to the analysis of variance test followed by Tukey's multiple comparison test, at a 5% level of significance. Results: The analysis of the monomer/polymer degree of conversion did not reveal any difference between the three groups of resins (medium pink, with and without nylon fibers and colorless resin); it was approximately 88%. The results did not show significant differences between the groups for each variable (p>0.05). Conclusion: The results showed that color and presence of nylon fibers in acrylic resins did not affect the properties analyzed in this study.


RESUMO Objetivo: Analisar se corantes e fibras de nylon influenciam nas propriedades de uma resina acrílica ativada por energia de micro-ondas. Métodos: Espécimes retangulares e em forma de disco foram confeccionados em resina acrílica rosa médio com e sem fibras de nylon e incolor sem fibras. Para obter os espécimes retangulares, foi utilizada uma matriz de aço inoxidável com as seguintes dimensões: 64 X 10 X 3 (± 0,5mm) e para obter os espécimes em forma de disco, foi utilizada uma matriz com 50mm (± 0,5mm) de diâmetro e 0,5mm (±0,05mm) de espessura. Os mesmos foram randomizados para formar os grupos controle (acrílico incolor sem fibras) e experimentais (rosa médio com e sem fibras), sendo cada grupo composto por dez (10) espécimes retangulares e cinco (5) em forma de disco. Foram os mesmos então submetidos a seis (6) ensaios (resistência ao impacto izod, n=10; dureza knoop, n=10; temperatura de transição vítrea, n=3; sorção e solubilidade, n=5; grau de conversão, n=1; resistência à flexão e módulo de flexão, n=10). Todas as variáveis foram submetidas à análise de variância seguida pelo teste de comparações múltiplas de Tukey, com nível de significância de 5%. Resultados: O grau de conversão foi de 88% para os 3 grupos de resinas e os resultados não mostraram diferença estatisticamente significativa entre os mesmos para cada variável (p>0,05). Conclusão: Os resultados mostraram que o corante e a presença de fibras de nylon em resina acrílica não afetaram as propriedades analisadas nesse estudo.

8.
Braz. dent. sci ; 20(4): 124-129, 2017. ilus, graf
Article in English | LILACS, BBO | ID: biblio-878134

ABSTRACT

Objectives: The aim of this study was to evaluate a Y-TZP ceramic sintered by a microwave protocol on volume shrinkage and surface roughness. Material and Methods: Twenty four (N=24) Y-TZP discs were fabricated by milling in CAD/ CAM for size standardization. The mean final dimensions of the specimens were 15 mm X 1.6 mm. Samples were divided into 2 groups (n=12): conventional resistive heating sintering protocol (C - Control) and microwave sintering protocol (MO - experimental). For the characterization of the specimens, surface roughness (Ra and Rz parameters) was evaluated with a roughness tester, and volume shrinkage was measured with a hand micrometer. Data were statistically evaluated by Student's t and Mann-Whitney U tests (α=0.05). Results: The roughness results were: 0.25 µm ± 0.02 (Ra) and 2.68 µm ± 0.666 (Rz) for the MO samples; 0.26 µm ± 0.04 (Ra) and 2.73 µm ± 0.461 (Rz) for the C group (Ra: p = 0.19; Rz: p = 0.81). The shrinkage results was: MO (21.02% ± 2.70) and C (20.10% ± 0.52) (p = 0.274). Conclusion: The conventional and microwave sintering methods were similar regarding surface roughness and volume shrinkage of Y-TZP dental ceramic (AU)


Objetivo: avaliar uma cerâmica de zircônia estabilizada com óxido de ítrio (Y-TZP) sinterizada por um protocolo em micro-ondas quanto à contração volumétrica e a rugosidade superficial. Material e Métodos: Vinte e quatro discos (n = 24) de Y-TZP foram fresados em CAD / CAM para padronização do tamanho. A dimensões finais médias dos corpos de prova foram de 15 mm X 1,6 mm. As amostras foram divididas em 2 grupos (n = 12): protocolo de sinterização convencional por aquecimento resistivo (C - Controle) e protocolo de sinterização por microondas (MO - experimental). A caracterização das amostras foi realizada pela avaliação da rugosidade superficial, com um rugosímetro (parâmetros Ra e Rz) e da contração volumétrica, medida com um micrômetro manual. Os dados foram estatisticamente avaliados pelos testes de t-Studant e U-Mann-Whitney (α=0,05). Resultados: Os resultados de rugosidade foram: 0,25 µm ± 0,02 (Ra) e 2,68 µm ± 0,666 (Rz) para o MO; e 0,26 µm ± 0,04 (Ra) e 2,73 µm ± 0,461 (Rz) para o grupo C (Ra: p = 0,19; Rz: p = 0,81). A contração volumétrica foi de: MO (21,02% ± 2,70) e C (20,10% ± 0,52) (p = 0,274). Conclusão: os métodos de sinterização convencionais e de microondas são semelhantes, no que diz respeito à rugosidade superficial e retração de volume da cerâmica dental Y-TZP. (AU)


Subject(s)
Ceramics
9.
RGO (Porto Alegre) ; 63(3): 315-318, July-Sept. 2015.
Article in English | LILACS | ID: lil-765052

ABSTRACT

Objective: The objective of this study was to evaluate the effectiveness of disinfection methods in microwave and immersion in peracetic acid in heat-cured, self-cured and microwave-cured acrylic resin, contaminated with Candida albicans.Methods: Five specimens were prepared for each type of acrylic resin. All were infected with Candida Albicans, incubated at 37°C for 24 hours. The group which underwent microwave energy was irradiated with a power of 840W for 1 minute and the other group underwent disinfection by soaking of 0.2% peracetic acid for 5 minutes.Results: All samples proved to be contaminated after the incubation period. After the different processes of disinfection, both immersion in 0.2% peracetic acid as microwave irradiation were effective in disinfection of the 3 types of acrylic resins contaminated by Candida Albicans.Conclusion: Concluded that soaking in 0,2% peracetic acid for 5 minutes with microwave irradiation power 840W for 1 minute are effective methods for disinfecting heat-cured acrylic resin, self-cured acrylic resin and microwave-cured acrylic resin, contaminated with Candida Albicans.


Objetivo: Avaliar a eficácia dos métodos de desinfecção em microondas e imersão em ácido peracético em resina acrílica termopolimerizável, autopolimerizável e resina acrílica polimerizada por microondas, contaminadas com Candida albicans.Métodos: Cinco amostras foram preparadas para cada tipo de resina acrílica. Todas foram infectadas com Candida Albicans, incubadas a 37 ° C durante 24 h. O grupo submetido a energia de microondas foi irradiada com uma potência de 840W durante 1 minuto e o outro grupo foi submetido a desinfecção por imersão de ácido peracético a 0,2% durante 5 minutos.Resultados: Todas as amostras mostraram estar contaminadas depois do período de incubação. Depois dos diferentes processos de desinfecção, tanto a imersão em 0,2% de ácido peracético, como a irradiação de microondas foram eficazes na desinfecção dos 3 tipos de resinas acrílicas contaminados por Candida Albicans.Conclusão: Concluiu-se que a imersão em ácido peracético 0,2% durante 5 minutos e a irradiação de microondas com potência de 840W durante 1 minuto são métodos eficazes para a desinfecção de resina acrílica termopolimerizável, resina acrílica autopolimerizável e resina acrílica polimerizada por microondas, contaminados com Candida Albicans.

10.
Eng. sanit. ambient ; 20(2): 289-296, abr.-jun. 2015. tab, ilus
Article in Portuguese | LILACS | ID: lil-759308

ABSTRACT

A Norma Técnica CETESB P2.111/2007 foi tomada como base para avaliar a desinfecção de resíduos de serviços de saúde (RSS) por micro-ondas, através da comparação dos resultados provenientes da utilização da norma, ou seja, com endósporos de Bacillus atropheus em suspensão no interior de ampolas introduzidas nos RSS, com os obtidos nos endósporos dispersos na superfície das partículas. Os resultados foram ajustados à cinética de primeira ordem e à Lei de Arrhenius para obtenção das energias de ativação (Ea) e dos fatores pré-exponenciais (k0). A Ea obtida nos endósporos em suspensão nas ampolas (99-45 J.mol-1) foram sensivelmente menores quando comparadas com as Ea (9.203-5.782 J.mol-1) provenientes da inativação dos endósporos dispersos sobre os RSS, para k0 praticamente constantes (0,26 e 0,23 min-1, respectivamente). Portanto, a resistência à inativação dos endósporos foi bastante afetada pelo meio suporte utilizado, tendo sido mais sensíveis à exposição a micro-ondas no meio líquido do que no meio sólido.


The Technical Standard CETESB P2.111/2007 was tested to evaluate the microwave healthcare waste disinfection, by comparing the results obtained using the standard procedure, i.e. Bacillus atropheus spores in suspension inside vials distributed in the waste, with those obtained with spores dispersed on the particles surface. The experimental results were adjusted based on first-order kinetic model and Arrhenius Law to determine the activation energies (Ea) and the pre-exponential factors (k0). The Ea in spores suspension inside vials (99-45 J.mol-1) were significantly lower when compared with Ea (9,203-5,782 J.mol-1) from the inactivation of dispersed spores in the waste to k0 practically constant (0.26 and 0.23 min-1, respectively). Therefore, spore resistance to inactivation was greatly affected by the support medium used, since the spores were more susceptible to microwave exposition in liquid medium than in the solid one.

11.
Rev. bras. epidemiol ; 17(3): 577-581, Jul-Sep/2014. tab
Article in English | LILACS | ID: lil-733189

ABSTRACT

Objective: To Analyze the association between prevalence of fatigue referred by physical therapists and their occupational exposure to radiation emitted by therapeutic microwave diathermy equipment. Methods: A Cross-sectional study conducted in 193 physical therapists from four cities of the west of Paraná State, Brazil. A specified structured web questionnaire was applied for collecting data about microwave diathermy exposition and potential confounders, plus the Multidimensional Assessment of Fatigue (MAF). Statistical analysis included logistic regression and Student's t-test. Results: The prevalence of fatigue in the category exposed to microwave diathermy was higher (15.0%) than in non-exposed (2.9%). On multivariate logistic regression, a significant independent association between exposure to microwave diathermy and prevalence of fatigue was observed (odds ratio 4.93; 95% confidence interval 1.04 - 23.25; p = 0.04). The Student's t-test showed significant difference between the number of hours exposed to diathermy microwave, being 3,839.1 within physical therapists who referred fatigue and 497.6 within others (p = 0.004). Conclusion: The results demonstrate a significant and independent association between occupational exposure of physical therapists to radiation of microwave diathermy and prevalence of fatigue. Therefore, occupational safety guidelines aimed at these professionals as a prevention of possible adverse effects, as well as the replication of this study are suggested. .


Objetivo: Analisar a associação entre a prevalência de fadiga referida por fisioterapeutas e a exposição desses profissionais à radiação emitida por equipamentos terapêuticos de diatermia por micro-ondas. Metodologia: Foi realizado estudo de corte transversal com 193 fisioterapeutas de quatro municípios da região Oeste do Estado do Paraná, Brasil. Foi aplicado, via eletrônica, questionário estruturado especialmente para a coleta de dados sobre a exposição ocupacional à radiação emitida por equipamentos de diatermia por micro-ondas e potenciais fatores de confusão, acrescido do questionário de Avaliação Multidimensional de Fadiga. A análise estatística incluiu regressão logística e teste t de Student. Resultados: A prevalência de fadiga na categoria expostos a micro-ondas foi maior (15,0%) do que em não expostos (2,9%). Na regressão logística multivariada foi observada associação independente significante entre a exposição ocupacional de fisioterapeutas à radiação de diatermia por micro-ondas e a prevalência de fadiga (odds ratio 4,93; intervalo de confiança de 95% 1,04 - 23,25; p = 0,04). O teste t de Student mostrou diferença significante entre o número total de horas de exposição à radiação de diatermia por micro-ondas, sendo de 3.891,1 entre os fisioterapeutas que referiram fadiga e de 497,6 entre os que não referiram (p = 0,004). Conclusão: Os resultados demonstraram associação significante entre a exposição ocupacional de fisioterapeutas à radiação emitida por equipamentos de diatermia por micro-ondas e fadiga, portanto, são sugeridas orientações de segurança ocupacional, dirigidas a esses profissionais, como medida preventiva ...


Subject(s)
Adult , Female , Humans , Male , Diathermy/adverse effects , Fatigue/epidemiology , Fatigue/etiology , Microwaves/adverse effects , Occupational Diseases/epidemiology , Occupational Diseases/etiology , Occupational Exposure/adverse effects , Physical Therapy Specialty , Cross-Sectional Studies , Diathermy/instrumentation , Prevalence
12.
Ciênc. rural ; 44(5): 925-930, maio 2014. ilus, tab
Article in Portuguese | LILACS | ID: lil-707048

ABSTRACT

A determinação de umidade em grãos é um parâmetro de qualidade importante, uma vez que o teor de água presente no alimento tem influência tanto no armazenamento quanto na comercialização do produto. Os métodos usados como referência na determinação de umidade em grãos empregam a perda por dessecação em estufa (LOD). Apesar de ser de fácil execução, esse método dispende cerca de 24h de aquecimento, normalmente, em 105°C, para obtenção do resultado. No presente estudo, é proposta a determinação da perda por dessecação assistida por radiação micro-ondas (MALOD) para amostras de grãos moídos de arroz branco, arroz integral, ervilha, feijão branco, feijão carioca, feijão preto, grão-de-bico, lentilha e milho, buscando reduzir o tempo de análise. Parâmetros como potência irradiada, massa de amostra, influência do recipiente e tempo de irradiação com micro-ondas foram avaliados e os resultados obtidos foram comparados com a LOD (sugerido pelo MAPA) e, também, por radiação infravermelha (IRLOD). Verificou-se que não houve diferença significativa do teor de umidade empregando massas de amostra entre 2 e 15g por LOD, porém, para MALOD, ocorreram hot spots (carbonização da amostra) com massas superiores a 2g. Resultados similares de umidade foram encontrados entre os diferentes recipientes (pesa-filtros e frascos de polipropileno), optando-se pela utilização dos frascos de polipropileno, devido à diminuição do tempo de pré-condicionamento. A MALOD apresentou concordância entre 94% e 102% com o método oficial, sendo que apenas 50min foram suficientes para determinar a umidade para todos os grãos, perfazendo uma redução do tempo de análise de até 29 vezes.


The determination of moisture in grains is an important quality parameter, since the water content in food has an influence on both storage and commercialization of product. The methods often used for determination of moisture in grains are based on the loss on drying in an oven (LOD). Although it is easy to perform, this method spent about 24h of heating, usually at 105°C, to obtain the result. In the present study is proposed the determination of the loss on drying assisted by microwave radiation (MALOD) for samples of grounded grains of white rice, brown rice, peas, beans, bean, black beans, chick-peas, lentils and corn, in order to reduce the analysis time. Parameters such as irradiated power, sample mass, container and influence of irradiation time with microwave were evaluated and the results were compared with those obtained by LOD (suggested by MAPA) and also by infrared radiation (IRLOD). It was found that there was no significant difference in moisture content in samples between 2 and 15g using LOD, but there were hot spots for MALOD (carbonization of the sample) with masses higher than 2g. Similar results for moisture content were found by the use of different containers (glass weighing bottle and polypropylene flasks) and the polypropylene cups were selected due to the reduction of conditioning time of flasks. The agreement of MALOD with the official method was between 94% and 102% and only 50min were enough to determine the moisture of all grains, making a reduction of analysis time by 29 times.

13.
Article in Portuguese | LILACS | ID: lil-691771

ABSTRACT

O creme base não iônico descrito no Formulário Nacional foi preparado com duas formas de aquecimento: uma clássica, em banho-maria e chapa com as duas fases separadas; e uma alternativa, em forno micro-ondas com as fases juntas. Procedeu-se o estudo da estabilidade preliminar onde foram avaliados variação dos valores de pH, condutividade, viscosidade e espalhabilidade entre as bases. Estas foram armazenadas em diferentes condições como preconizado no Guia de Estabilidade de Produtos Cosméticos. As bases não apresentaram diferença significativa em relação a pH, condutividade e espalhabilidade máxima. A avaliação reológica demonstrou comportamento não newtoniano, com fluxo plástico e tixotropia. A base aquecida em micro-ondas demonstrou maior viscosidade e menor espalhabilidade, provavelmente decorrente da maior homogeneidade das gotículas observadas na análise microscópica. Pode-se observar que a utilização de outra fonte de aquecimento mais rápida não modificou o produto, podendo ser utilizada como forma alternativa.


The non-ionic cream base described in the Brazilian National Formulary was prepared with two heating methods: one conventional, using a water bath and heating plate, with the two phases heated separately, and one alternative, in a microwave oven, with the phases heated together. A preliminary stability study assessed differences between the bases in pH, conductivity, viscosity and spreadability, after exposure to various treatments and at the end of a 15-day period at several temperatures, as recommended by the Cosmetic Products Stability Guide. No significant differences in pH, conductivity or maximum spreadability were observed. Rheological tests showed non-Newtonian behavior, with plastic flow and thixotropy. The base heated in the microwave oven showed higher viscosity and lower spreadability, probably due to the greater homogeneity of the droplets observed under the microscope. Thus, it can be concluded that the faster heating method did not change the product and may be used as an alternative approach to preparation of the cream base.


Subject(s)
Cosmetic Stability , Cosmetic Technology , Cosmetics/analysis , Emulsions/pharmacology
14.
J. Health Sci. Inst ; 30(4)out.-dez. 2012. tab
Article in Portuguese | LILACS | ID: lil-673905

ABSTRACT

Objetivo - Analisar o efeito antimicrobiano do forno de micro-ondas em materiais domésticos contaminados, utilizando um esterilizador específico. Métodos - Amostras coletadas de chupetas, bico de mamadeira, escova dental e esponjas de pia de cozinha foram inoculadas em meios de cultura, antes e depois da desinfecção pelas micro-ondas. Resultados - Todos os objetos estavam contaminados por vários tipos de microrganismos e após a exposição dos materiais às micro-ondas não foi observado crescimento microbiano. Conclusão - O esterilizador específico para o forno de micro-ondas pode ser utilizado como método para controle do crescimento microbiano em diversos materiais, como utensílios domésticos.


Objective - To analyze the antimicrobial effects of microwaves on some contaminated household materials using a specific sterilizer. Methods - Samples of pacifiers, bottle nipple, toothbrush and kitchen sink sponges were inoculated in microbiology culture media before and after disinfection by using microwave oven. Results - Microbial growth of various species of microorganisms was observed in all objects and exposition to the microwaves inhibited infection proliferation on these household materials. Conclusion - The specific sterilizerfor the microwave oven may be used as a method for controlling microbial growth in a variety of materials such as housewares.


Subject(s)
Biological Contamination , Disinfection , Microwaves
15.
Rev. bras. cir. plást ; 27(4): 518-522, out.-dez. 2012. tab
Article in Portuguese | LILACS | ID: lil-675890

ABSTRACT

INTRODUÇÃO: Fluidos cristaloides são comumente aquecidos em forno de micro-ondas, para uso endovenoso ou subcutâneo (em lipoaspirações). A literatura médica é pobre em trabalhos estabelecendo parâmetros científicos para esse processo. O objetivo deste estudo foi estudar experimentalmente o aquecimento de solução salina (cloreto de sódio a 0,9%), a partir de diferentes temperaturas iniciais, deduzir uma equação para permitir o cálculo de parâmetros de aquecimento e estudar o decréscimo de temperatura da solução aquecida. MÉTODO: Frascos para infusão endovenosa (500 ml e 1.000 ml) de solução salina tiveram sua temperatura inicial ajustada para 15°C, 20°C e 25°C, sendo aquecidos por micro-ondas até 60 segundos (500 ml) e 120 segundos (1.000 ml). A temperatura da solução salina foi medida durante e ao final do aquecimento e até 30 minutos após esse processo. A partir dos resultados, foi deduzida uma equação. RESULTADOS: O aquecimento por 60 segundos elevou a temperatura de frascos de 500 ml de solução salina em cerca de 20°C. Foram necessários 120 segundos para a mesma elevação de temperatura de frascos de 1.000 ml. A equação deduzida foi: TIF = TII + [0,165 x Tempo (segundos) / Volume (litros)], onde TIF = temperatura interna final e TII = temperatura interna inicial. Não foram encontradas diferenças significantes entre as temperaturas interna e externa após o aquecimento. CONCLUSÕES: A determinação da temperatura inicial é fundamental na obtenção da temperatura final desejada, após o aquecimento de fluidos cristaloides por micro-ondas. Uma equação pôde ser deduzida, tornando possível o cálculo da temperatura final a partir de várias temperaturas iniciais. A temperatura externa dos frascos reflete adequadamente sua temperatura interna.


BACKGROUND: Crystalloids are commonly heated in microwave ovens for intravenous or subcutaneous usage (e.g., in liposuction). However, few studies have empirically determined the parameters for this procedure. This study experimentally evaluated the heating of saline solution (sodium chloride 0.9%) at different initial temperatures to derive an equation to calculate heating parameters as well as the temperature decrease in saline solutions after heating. METHODS: The initial temperature of intravenous pouches containing saline solution (500 and 1,000 mL) was adjusted to 15°C, 20°C, or 25°C. The 500 and 1,000 mL pouches were then warmed in a microwave (900 W) for 60 and 120 seconds, respectively. The temperature of the saline solution was measured during heating and immediately and 30 minutes after heating. An equation was derived from the results. RESULTS: Warming the 500 and 1,000 mL pouches for 60 and 120 seconds, respectively, at 900 W increased the temperature of these pouches by 20°C. The derived equation was as follows: final temperature = initial temperature + [0.165 × time (s)/volume (L)]. No significant differences were found between the internal and external temperatures of the pouches after heating. CONCLUSIONS: Determining the initial temperature of crystalloid solutions is essential for obtaining the desired temperature after microwave warming. The equation derived in the present study enables calculation of the final temperature of solutions with various initial temperatures. The external temperature of the pouches accurately reflects their internal temperature.


Subject(s)
Humans , Hypothermia , Infusions, Parenteral , Lipectomy , Microwaves , Reference Standards , Case Reports , Crystallography , Methods , Saline Solution, Hypertonic
16.
Ciênc. rural ; 42(6): 1102-1109, jun. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-640727

ABSTRACT

O Brasil está entre os dez maiores produtores de arroz do mundo. Devido ao beneficiamento, boa parte dos grãos é quebrada, gerando um subproduto de baixo valor comercial. A farinha de arroz normalmente é produzida a partir de grãos quebrados e é utilizada em produtos manufaturados devido a suas propriedades funcionais. Visando à obtenção de farinhas com propriedades funcionais diferenciadas e assim ampliar sua utilização como ingrediente em diferentes aplicações na indústria de alimentos, o objetivo deste trabalho foi avaliar o efeito da umidade e do tempo de torra (variáveis independentes), em micro-ondas, sobre as características funcionais de farinhas de arroz da cultivar 'IRGA 417'. Utilizou-se delineamento experimental composto central. A variação do teor de amilose (TA) entre as farinhas de arroz torradas foi de 16-30g (100g)-1, sendo que nos menores tempos de torra (até 13,3min) e umidade acima de 18,5g (100g)-1 observaram-se os maiores TA. Ocorreu elevação do índice de absorção de água (IAA) à medida que aumentou o tempo de torra das farinhas de arroz. Os valores mais elevados de índice de solubilidade em água (ISA) (25%) foram encontrados para as farinhas de arroz com umidade acima de 22g (100g)-1. Com o aumento do tempo de torra, ocorreu diminuição do pico de viscosidade, viscosidade final e de tendência a retrogradação das farinhas torradas. O contrário foi observado para a quebra de viscosidade. Conclui-se que a torração em micro-ondas pode ampliar as aplicações da farinha de arroz na indústria de alimentos em função das mudanças funcionais resultantes.


Brazil is among the ten largest producers of rice in the world. Due to processing, most of the grains is broken, causing a by-product of low commercial value. Rice flour is usually produced from broken grains and used in manufactured products because of their functional properties. Aiming to obtain flours with different functional properties and thus extend its use as an ingredient in different applications in the food industry, the objective was to evaluate the effect of moisture content and roasting time (independent variables), in the microwave, on the functional characteristics of flour from rice variety 'IRGA 417'. We used central composite rotational experimental design. The variation of amylose content (TA) between the roasted rice flour was 16-30g (100g)-1, and roasting in the shortest times (until 13.3min) and humidity above 18.5g (100g)-1, we observed the highest TA. An elevation of the water absorption index (WAI) increased as the roasting time of rice flours. The highest values of water solubility index (WSI) (25%) were found for rice flour with humidity above 22g (100g)-1. With increased roasting time diminished the peak viscosity, final viscosity and setback of roasted flour. On the contrary was observed for the breakdown of viscosity. It is concluded that roasting in a microwave can expand the applications of rice flour in the food industry according to the functional changes that result.

17.
RGO (Porto Alegre) ; 59(2): 237-242, abr.-jun. 2011. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-874581

ABSTRACT

Objetivo: Avaliar o efeito do tratamento por energia de micro-ondas sobre as propriedades de resistência à flexão e microdureza da resina acrílica de ativação química Dencrilay Speed® (Dencril, Pirassununga, Brasil).Métodos: Foram confeccionados 24 corpos-de-prova separados em quatro grupos de acordo com o ciclo de tratamento por energia de micro-ondas. O G1 (controle) não recebeu tratamento algum. Os grupos G2, G3 e G4 foram imersos em 200ml de água destilada e irradiados em micro-ondas a 650W durante 5, 3 e 1 minuto, respectivamente. Cada grupo (n=6) foi submetido ao ensaio de resistência à flexão de três pontos e ao teste de microdureza Vickers (após 48 horas de armazenamento). Resultados: Os valores médios (Mpa) e desvios-padrão para o teste de resistência à flexão foram: G1 86,04 ± 10,32 a; G2 100,1 ± 5,52 ab; G3 102,04 ± 5,41 b; G4 104,81 ± 14,17 b. Os valores médios encontrados em microdureza (VHN) foram: G1- 21,98 ± 0,82 a; G2- 20,15 ± 1,24 b; G3- 19,69 ± 0,91 b; G4- 19,44 ± 0,41 b. Conclusão: O tratamento por energia de micro-ondas elevou a resistência à flexão e reduziu a microdureza da resina acrílica avaliada.


Objective: This study assessed the effectiveness of microwave energy treatment on the flexural resistance and microhardness of the chemically-activated acrylic resin Dencrilay Speed®. Methods: Twenty-four specimens were prepared and divided into 4 groups according to microwave-energy treatment cycle. G1 (control) did not receive any treatment. The specimens in groups G2, G3 and G4 were immersed in 200mL of distilled water and then microwaved in a 650W oven for 5, 3 and 1 minutes, respectively. Each group (n=6) was submitted to a three-point flexural strength test and to a Vickers hardness test after a 48-hour storage. Results: The mean values (MPa) and standard deviations for the flexural strength test were: G1 86.04 ± 10.32 a; G2 100.1 ± 5.52 ab; G3 102, 04 ± 5.41 b; G4 104.81 ± 14.17b. The mean values found for the hardness test (VHN) were: G1-21.98 ± 0.82 a; G2-20.15 ± 1.24 b; G3- 19,69 ± 0.91 b; G4-19.44 ± 0.41 b. Conclusion: Microwave treatment increased the flexural strength and reduced the microhardness of chemically-activated acrylic resins.


Subject(s)
Microwaves , Denture, Complete , Acrylic Resins
18.
Acta amaz ; 41(2): 297-302, 2011. tab
Article in Portuguese | LILACS, VETINDEX | ID: lil-586487

ABSTRACT

Neste trabalho, a espécie Piper hispidinervum (pimenta longa), endêmica do estado do Acre, foi cultivada na região do Vale do Itajaí - SC, e sua adaptação foi avaliada em relação à composição química do óleo essencial obtido pelos processos de hidrodestilação convencional e por micro-ondas. O safrol foi identificado como o constituinte majoritário do óleo essencial desta espécie, o qual foi empregado como parâmetro de avaliação da capacidade de adaptação desta planta à região sul do Brasil, já que a proposta abrange avaliar a utilização desta espécie como fonte alternativa de safrol, em substituição a Canela Sassafrás (Ocotea odorifera), espécie muito explorada até a década de 90 nesta região. As amostras da planta foram obtidas de diferentes regiões do Acre e foram cultivadas na estação experimental da EPAGRI - Itajaí-SC. O óleo essencial das folhas forneceu um teor médio de safrol entre 76,6% e 89,9%. A análise por CG-DIC e CG-EM do óleo com maior concentração de safrol, apresentou os seguintes constituintes: safrol (89,93%), α-terpineno (0,35%), (E)-ß-ocimeno (0,54%), terpinoleno (3,10%), valenceno (0,21%), (Z)-ß-bisaboleno (1,70%) e guaiol (0,29%).


In this work a Piper hispidinervum specie (long pepper), endemic from the Acre state, was grown in Itajaí Valley in Santa Catarina State, and its adaptation was evaluated in relation to chemical composition of essential oil obtained by traditional hydrodistillation and microwave hydrodistillation. The safrole was identified as the major constituent of the essential oil of this specie, which was used as a measure of evaluation of the adaptation capacity of this plant in the southern Brazil, as the proposal includes the evaluation of the usage of this specie as an alternative source of safrole, replacing Sassafras Cinnamon (Ocotea odorifera), widely explored specie in this region until the 90's decade. The plant samples were obtained from different regions of the Acre state and were cultivated at the experimental station of EPAGRI Itajaí - SC. The essential oil of the leaves provided an average content of safrole between 76.6% and 89.9%. The analysis by GC-FID and GC-MS of the oil with higher safrole content, presented the following relative constitution: safrole (89.93%), α-terpinene (0.35%), (E)-ß-ocimene (0.54%), terpinolene (3.10%), valencene (0.21%), (Z)-ß-bisabolene (1.70%) and guaiol (0.29%).


Subject(s)
Safrole , Oils, Volatile , Piper , Microwaves
19.
Araraquara; s.n; 2011. 158 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-866378

ABSTRACT

Este estudo in vivo teve como objetivos avaliar: 1. a prevalência das diferentes espécies de Candida em pacientes diabéticos portadores de estomatite protética e compará-la àquela de pacientes não diabéticos com/sem estomatite protética; 2. a eficiência de dois tratamentos para estomatite protética em pacientes diabéticos: terapia antifúngica com nistatina e desinfecção de próteses totais por micro-ondas. Para isso, 210 pacientes usuários de prótese totais foram selecionados e distribuídos em três grupos de estudo. O grupo controle - GC foi formado por 90 pacientes não diabéticos e com mucosa oral saudável; os grupos experimentais foram formados por portadores de estomatite protética, sendo 80 pacientes não diabéticos - EPND e 40 diabéticos do tipo 2 controlados - EPD. Uma avaliação intra-oral dos pacientes dos grupos experimentais foi realizada e a aparência clínica da mucosa inflamada foi classificada de acordo com os critérios de Newton em graus I, II ou III. Coletas microbiológicas das próteses totais foram realizadas com swab estéril e plaqueadas em meio CHROMagar Candida. Em seguida, os procedimentos de identificação foram realizados: análise de microcultivo, teste de triagem fenotípica em caldo hipertônico e testes bioquímicos (ID-32C). Os resultados obtidos foram analisados por Intervalo de Confiança de Bonferroni e testes Exato de Fisher e Qui Quadrado (α=0,05). Os 40 pacientes diabéticos foram, então, submetidos ao tratamento da estomatite protética. Para isso, foram aleatoriamente distribuídos em 2 grupos (n=20): grupo NIS ­ tratamento com antifúngico tópico nistatina (suspensão oral - 100.000UI/mL), 4 vezes ao dia, por 14 dias; grupo MIC ­ tratamento por meio da irradiação das totais por micro-ondas (650W / 3 minutos), 3 vezes por semana, por 14 dias. Dois parâmetros foram utilizados para avaliar a efetividade dos tratamentos: microbiológico (coletas de material das próteses e das mucosas palatinas com swab estéril para quantificação de colônias viáveis ­ ufc/mL e identificação de Candida spp.) e clínico (tomadas fotográficas intra-orais das mucosas palatinas infectadas). Todos os pacientes foram submetidos a estes procedimentos previamente ao início dos tratamentos, ao seu final, e 30, 60 e 90 dias decorridos do seu início. Os valores de log10ufc/mL foram analisados estatisticamente por ANOVA subjacente a um modelo linear com efeitos aleatórios. A prevalência das espécies de Candida foi avaliada pelo teste Qui Quadrado. As avaliações qualitativas das fotografias intra-bucais e a análise da inflamação ao longo do tempo foram avaliadas, respectivamente, pelos testes Exato de Fisher e Mann-Whitney (α>05). Os resultados observados demonstraram que a C. albicans foi a espécie predominante em todos os grupos de estudo (p<0,016), seguida por C. tropicalis e C. glabrata (p>0,05). Não foram verificadas diferenças significantes (p>0,05) na prevalência de Candida spp. entre os grupos EPND e EPD. As prevalências de C. albicans e C. tropicalis foram significativamente superiores (p<0,01) nos grupos de pacientes com estomatite protética e a de C. tropicalis foi superior (p<0,05) nos pacientes diagnosticados com infecção grau III de Newton. Com relação aos tratamentos instituídos nos pacientes diabéticos, ambos reduziram significativamente (p<0,001) os valores de log10ufc/mL após 15 e 30 dias, não tendo sido encontradas diferenças estatisticamente significantes (p>0,05) entre os grupos de estudo. Não foram verificadas diferenças significantes (p>0,05) entre o número de pacientes curados e com recidivas, após a condução dos dois tratamentos. Com base nestes resultados, foi concluído que a prevalência de Candida spp. foi similar entre os pacientes diabéticos e não-diabéticos com estomatite protética. Apesar de a C.albicans ter sido a espécie mais frequentemente identificada em todos os pacientes avaliados, a prevalência de C. tropicalis foi superior nos pacientes com estomatite protética e naqueles com maior grau de inflamação, sugerindo que esta espécie pode estar envolvida com o início e a progressão da infecção. Além disso, a irradiação de próteses totais por micro-ondas pode ser utilizada com sucesso para tratar e prevenir o aparecimento de estomatite protética em pacientes diabéticos, apresentando a mesma efetividade de um método clássico de tratamento com antifúngico tópico


The aim of this in vivo study was to evaluate: 1. the prevalence of Candida spp. in well-controlled type 2 diabetic patients and compare it to that found in non-diabetics with/without denture stomatitis; 2. the efficacy of two treatments of denture stomatitis in diabetic patients: topical nystatin and denture microwave disinfection. Two hundred and ten denture wearer patients were divided into three groups of study. The control group - CG was formed by 90 individuals without diabetes or denture stomatitis and the experimental groups were formed by patients with denture stomatitis, being 80 non-diabetics - DSND and 40 well-controlled type 2 diabetics - DSD. Mucosal characteristics of denture stomatitis patients were classified in types I, II, and III, according to Newton's criteria. Mycological samples were taken from the dentures and cultured in CHROMagar's plates. Candida spp. were identified by micro-cultivation, hypertonic Sabouraud broth, and bioMérieux ID32C assays. Results were analyzed by means of Bonferroni corrected confidence interval, Fisher's exact test, and Chi-square analysis of several proportions (α=0.05). The 40 diabetic patients were divided into two groups (n=20) and submitted to two treatments for denture stomatitis: NYS group ­ patients were treated with topical nystatin, 4 times a day, for 14 days; MW group ­ patients had their dentures microwaved (650W / 3 minutes), 3 times per week, for 14 days. Mycological samples were taken from the palates and the tissue surface of the dentures for quantification and identification of Candida spp. and standardized photographs of the palates were taken for the clinical analysis. Microbiological and clinical evaluations were repeated at baseline, the end of treatments (day-14), and follow up (day-30, day60, day-90). Microbiological data were evaluated by ANOVA using a random effects statistical model,Tukey's post hoc test, and Chi-square test, while clinical results were analyzed by Mann-Whitney and Fisher's exact tests (α=0.05). According to the results, C. albicans was the most predominant species isolated in CG, DSND, and DSD groups (p<0.016), followed by C. tropicalis and C. glabrata (p>0.05). No significant differences were found in Candida spp. prevalence between DSND and DSD (p>0.05). The percentage frequencies of C. albicans and C. tropicalis in denture stomatitis groups (DSND and DSD) were significantly higher (p<0.01) than those in CG and the prevalence of C. tropicalis was significantly higher (p<0.05) in Newton's type III patients. Both NYS and MW treatments were considered successful in reducing the clinical signs of denture stomatitis and significantly reduced the values of cfu/mL from the palates and dentures at day-14 and day-30. Forty percent of patients had no signs of denture stomatitis at the end of both treatments. No significant differences (p>0.05) in the microbiological and clinical outcomes were revealed between the two treatments. It was concluded that the prevalence of Candida spp. was similar between diabetic and non-diabetic patients with denture stomatitis. Despite C. albicans was the most commonly isolated organism, the prevalence of C. tropicalis increased in patients with denture stomatitis and in those with the highest degree of inflammation, suggesting that this species may play an important role in the progression of this infection. In addition, denture microwave disinfection was as effective as nystatin on the treatment of well-controlled type 2 diabetic patients with denture stomatitis


Subject(s)
Humans , Candida , Nystatin , Disinfection , Diabetes Mellitus , Stomatitis, Denture , Microwaves , Denture, Complete , Chi-Square Distribution , Analysis of Variance , Statistics, Nonparametric
20.
Pediatr. mod ; 45(6)nov.-dez. 2009.
Article in Portuguese | LILACS | ID: lil-540863

ABSTRACT

O presente trabalho enfatiza que o Banco de Leite Humano (BLH) da Maternidade Escola Januário Cicco, da Universidade Federal do Rio Grande do Norte, coleta, processa e controla a qualidade do leite materno doado. No entanto, este processamento pode interferir na composição de nutrientes, como a vitamina A, que pode ser facilmente destruída pela exposição à luz e ao oxigênio. Sendo esta vitamina um micronutriente essencial para a saúde, por desempenhar papel importante em diversos processos vitais, foi avaliado o efeito do descongelamento por banho-maria e forno micro-ondas sobre os níveis de retinol do leite materno.


Subject(s)
Humans , Milk Banks , Infant Nutrition/standards , Vitamin A/analysis , Milk, Human
SELECTION OF CITATIONS
SEARCH DETAIL